路由器未接地引起的无法拨号故障解决

www.net130.com     日期:2007-11-13    浏览次数:
出处:赛迪网

故障现象
 
  笔者某次配置了一个AM模块。出现了一个奇怪的问题。配置好后,拨入时没有Modem拨号声。只有电话的声。并且音指示灯也不亮。当笔者拔下模块上的电话线时。指示灯亮了。

配置
 
    620#sh run 
    Building configuration...
    Current configuration : 866 bytes
    version 12.2  
    service timestamps debug uptime 
    service timestamps Jog uptime 
    no service password-encryption  
    hostname2620  
    enable secret 5  
    usernameuser password 0 Cisco  
    ip subnet-zero
    !  
    !
    no ip DOmain-lookup  
    ! 
    !  
    ! 
    !  
    interface FastEthernet0/0  
    ip address 136.0.0.254255.255.0.0  
    duplex auto 
    speed auto 
    !
    interface Group-Async1 
    ip unnumbered FastEthernet0/0  
    encapsulation ppp  
    async default routing 
    async mode interactive 
    peer default ip address pool lab 
    ppp authentication chap
    group-range 33 48 
    !
    ! 
    ip classless 
    no ip http server 
    ip pim bidir-enable 
    ! 
    !  
    line con 0  
    password cisco  
    line 33 48  
    login local  
    modem InOut  
    autocommand ppp  
    transport input all 
    autoselect ppp
    stopbits 1 
    flowcontrol hardware  
    line aux0  
    line vty 0 4  
    password Cisco  
    login 
    ! 
    no scheduler allocate  
    end 58 

诊断过程  
    笔者仔细检查配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系。没自动应答:多半是接地问题。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了。

排除心得  
    路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好?,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰。接路由器电源的时候如果有地线,一般不需要我们再接地了。